Oil in Water Analyses
Roemex perform routine oil in water determinations of produced
waters by solvent extraction and IR analysis utilising an
Infracal TOG/TPH analyser.
Determination of scale
and corrosion inhibitor residuals
Roemex perform routine analysis of produced waters for residual
levels of scale and corrosion inhibitors utilising the Hach
Lange DR2400 spectrophotometer and colourimetric techniques.
Biological Testing
Roemex can perform microbiological testing to determine the
presence of different bacterial types using test kits such
as Rapidchek II and the most probable number method. Roemex
can also evaluate the efficiency of biocides against different
planktonic and sessile bacterial populations (single or field
isolated).
Hydrocarbon Analyses
Chemists at the Roemex laboratory conduct quantitative analysis
on black oil in relation to the evaluation of wax and asphaltene
inhibitors. All API/IP-level analysis is contracted to NAMAS-accredited
laboratories.
Water Analysis
For routine 12-ion brine chemistry analysis, Roemex have an
agreement with a local NAMAS-accredited laboratory.
Deposit Analysis
Roemex can characterise generic solid types by their solubility
and can provide indications as to the form of solid materials.
For more in-depth analysis of solids such as scales, Roemex
work with Aberdeen-based analytical companies to obtain x-ray
diffraction (XRD) and scanning electron microscopy (SEM) data.
|